Golestan University of Medical Sciences Repository

Technetium-99m methoxyisobutylisonitrile scintigraphy in the assessment of cold thyroid nodules: Is it time to change the approach to the management of cold thyroid nodules?

Riazi, A. and Kalantarhormozi, M. and Nabipour, I. and Eghbali, S.S. and Farzaneh, M. and Javadi, H. and Ostovar, A. and Seyedabadi, M. and Assadi, M. (2014) Technetium-99m methoxyisobutylisonitrile scintigraphy in the assessment of cold thyroid nodules: Is it time to change the approach to the management of cold thyroid nodules? Nuclear Medicine Communications, 35 (1). pp. 51-57.

Full text not available from this repository.

Abstract

Background: Scanning with technetium-99m methoxyisobutylisonitrile ( 99mTc-MIBI) is recommended for evaluating thyroid nodule metabolism. In addition, it may help differentiate between benign and malignant nodules; however, the efficacy of this technique has not been fully elucidated. Therefore, it is not currently performed for routine clinical application. This prospective study was conducted to investigate the clinical significance of 99mTc-MIBI scintigraphy in the assessment of patients with cold thyroid nodules. Patients and methods: This prospective study was conducted on 104 patients with cold thyroid nodules greater than 1 cm in diameter as detected on 99mTc-pertechnetate scintigraphy. Uptake of MIBI in thyroid nodules was compared with that in the surrounding normal thyroid tissue for both early and delayed images, and a score of 0-3 was assigned to each nodule as follows: 0, cold; 1, decreased; 2, equal; 3, increased. The thyroid scan was performed 20 and 40 min after intravenous injection of 555 MBq of 99mTc-MIBI. The patients underwent fine-needle aspiration cytology (FNAC). Detailed statistical parameters were determined on a per-nodule basis for each qualitative and quantitative scan analysis, as defined by histology. Results: A total of 104 patients (93 women and 11 men; mean age 40.76±11.40 years, range 20-73) with a total number of 167 cold nodules were included in this study. When 99mTc-MIBI uptake was regarded as the criterion of malignancy in 99mTc-MIBI scintigraphy, the accuracy was between 69.46 and 92.21 on using seven different methods. In addition, FNAC findings indicated a sensitivity of 66.66, a specificity of 100, a negative predictive value of 95.72, a positive predictive value of 100, and an accuracy of 96.06. Six malignant cold nodules were detected on a positive 99mTc-MIBI scan, which were determined as benign nodules on FNAC examinations. Conclusion: The study demonstrated that 99mTc-MIBI scanning can be complementary to other diagnostic techniques in patients with cold thyroid nodules. In addition, because of its availability, rather low cost, simple protocol, and objective semiquantitative information, 99mTc-MIBI scanning seems to hold promise in routine imaging of cold thyroid nodules. © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Item Type: Article
Additional Information: cited By 8
Uncontrolled Keywords: methoxy isobutyl isonitrile technetium tc 99m; pertechenetic acid tc 99m; tracer; unclassified drug, adult; aged; article; cold thyroid nodule; controlled clinical trial; controlled study; diagnostic accuracy; diagnostic test accuracy study; drug uptake; female; fine needle aspiration biopsy; gamma camera; goiter; histopathology; human; human tissue; image analysis; major clinical study; male; nodular goiter; nodular hyperplasia; predictive value; quantitative analysis; sensitivity and specificity; thyroid adenoma; thyroid cyst; thyroid nodule; thyroid papillary carcinoma, Adult; Aged; Female; Humans; Male; Middle Aged; Prospective Studies; Technetium Tc 99m Sestamibi; Thyroid Nodule; Young Adult
Subjects: مقالات نمایه شده محققین دانشگاه در سایت ,Web of Science ,Scopus
Divisions: معاونت تحقیقات و فناوری
Depositing User: GOUMS
Date Deposited: 13 Aug 2017 05:32
Last Modified: 13 Aug 2017 05:32
URI: http://eprints.goums.ac.ir/id/eprint/9381

Actions (login required)

View Item View Item